[ Order Now | Request Info ] |
Filter Pure Systems, Inc. |
Hydrotech®
HT 101 Series |
|
Hydro
Tap Drinking HT103
Series HTF101
Series CM
Series VCM
Series
|
|
HT 101 Series The Hydrotech® Reverse Osmosis Drinking Water System combines mechanical filtration with reverse osmosis technology for effective water treatment in point-of-use applications. The system is manufactured using the finest materials available, including NSF® approved plastics. The system is 100% tested and sanitized in preparation for shipment. Hydrotech® Drinking Water Systems are equipped with a patented Smartap® Water Quality Monitor which compares the feed water to the product water to determine membrane performance. The Smartap® Monitor reports the results by illuminating colored lights. The Smartap® Push Button Monitor is activated at the touch of a button. The Smartap® Faucet Monitor is actuated with each draw of water from the faucet, in addition, it monitors inlet valve operation. The integrity of this proven, leading edge technology provides the customer with consistent, reliable system performance. The Hydrotech® Reverse Osmosis System is backed by a two year limited waranty. The Smartap® water quality monitor is backed by a five year warranty. |
||||||||||||||
| OPTIONS SELECT MODULE, OUTPUT DESIGNATION, CONTAMINATION CLAIM AND FAUCET TO DETERMINE MODEL NUMBER | ||||||||||||||||
|
Module Configuration |
Output Designation°° |
Chemical - Mechanical Claims | Chemical - Mechanical - Nitrate Claims | |||||||||||||
|
WATER QUALITY MONITOR |
9 | 15 | 25 | 35 | 45 |
PRODUCT WATER FAUCET |
PRODUCT WATER FAUCET |
|||||||||
| Pushbutton Smartap® | 101 | 03 | 04 | 05 | 06 | 07 | Chrome | 001 | Stainless or Polymer | 101° | Chrome | 003 | Stainless or Polymer | 103° | ||
| Faucet Smartap® | 101 | 03 | 04 | 05 | 06 | 07 | Chrome | 002 | Stainless or Polymer | 102° | Chrome | 004 | Stainless or Polymer | 104° | ||
|
* System tested and certified by NSF International against ANSI/NSF 53 and ANSI/NSF 58 for specific contaminants as listed in the performance data sheet. |
||||||||||||||||
| ** Manufacturer's Reference Designation only. Refer to output Performance table for certified output performance. | ||||||||||||||||
| CHEMICAL REDUCTION PERFORMANCE | ||||||||||||||||
| Organic and Inorganic Contaminants | Influent AVG MG/L | Effluent AVG MG/L | Average % REJ |
Effluent MAX MG/L |
Minimum % REJ |
EPA MCL or ACTION LEVEL mg/L |
||||||||||
| Barium (Ba) | 10.7 | 0.15 | 99% | 0.60 | 94% | 2.0 | ||||||||||
| Cadmium (Cd) | 0.03 | 0.0005 | 98% | 0.00077 | 97% | 0.005 | ||||||||||
| Hexavalent Chromium (Cr) | 0.15 | 0.022 | 86% | 0.049 | 67% | 0.05 | ||||||||||
| Trivalent Chromium (Cr) | 0.17 | 0.02 | 88% | 0.02 | 88% | 0.05 | ||||||||||
| Copper (Cu) | 2.94 | 0.038 | 99% | 0.074 | 97% | 0.2 | ||||||||||
| Flouride (F) | 8.22 | 0.554 | 93% | 1.0 | 88% | 2.0 | ||||||||||
| Lead (Pd) | 0.146 | 0.0011 | 99% | 0.0015 | 99% | .0015 | ||||||||||
| Mercury (Hg) | 0.006 | 0.0005 | 91% | 0.0089 | 86% | 0.002 | ||||||||||
| Nitrates ~ Nitrites† (N) | 7.3 | 0.685 | 87% | 0.843 | 86% | 10.0 | ||||||||||
| Radium 226/228 (Ra) | 25pCi/L | 5pCi/L | 80% | 5pCi/L | 80% | 5pCi/L | ||||||||||
| Selenium (Se) | 0.1112 | 0.0042 | 96% | 0.01 | 91% | 0.05 | ||||||||||
|
† This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate (NO3) and 3 mg/L nitrite (NO2) in combination measured as 7.8 mg/L nitrogen (N) and is certified for nitrate/nitrite reduction in water supplies with a pressure of 280 kPa (40 psig) or greater. This system is not available in California. The contaminants or other substances removed or reduced by this water treatment device are not necessarily in your water. |
||||||||||||||||
| MECHANICAL FILTRATION PERFORMANCE | ||||||||||||||||
|
Contaminant Reduction |
Influent AVG MG/L | Effluent AVG MG/L | Average % REJ |
Effluent MAX MG/L |
Minimum % REJ | NSF Requirement % Rejection/MAX NTU | ||||||||||
| Asbestos | 671 | 0.347 | 99.95% | 3.7 | 99.45% | 7 million fibers (>10µm) per L | ||||||||||
| Cysts | 102,938 | 6.5 | 99.99% | 56 | 99.95% | 99.95% (3-4 micron size) | ||||||||||
| Turbidity | 19.4 NTU | 0.10 NTU | 99.95% | 0.19 NTU | 99% | 1.0 NTU | ||||||||||
|
Note: Certification for Cyst Reduction includes Cryptosporidium, Giadia lamblia and Entamoeba. The contaminants or other substances removed by this water treatment device are not necessarily in your water. |
||||||||||||||||
| OUTPUT PERFORMANCE | ||||||||||||||||
| Total Dissolved Solids (TDS) Reduction and System Production Product Water goes to Pressurized Tank | ||||||||||||||||
| Model Number | Influent AVG µMHO | Effluent AVG µMHO | Reject AVG % | Effluent MAX µMHO | Reject MIN % | Production Rate | Recovery Rating ‡ | |||||||||
| 10103 | 795 | 19 | 98% | 24 | 97% | 19 liter/day (5gal/day) | 34% | |||||||||
| 10104 | 795 | 51 | 94% | 74 | 91% | 28 liter/day (5gal/day) | 25% | |||||||||
| 10105 | 760 | 22 | 97% | 28 | 96% | 283 liter/day (5gal/day) | 21% | |||||||||
| 10106 | 761 | 32 | 96% | 44 | 94% | 34 liter/day (5gal/day) | 24% | |||||||||
| 10107 | 796 | 39 | 95% | 58 | 93% | 45 liter/day (5gal/day) | 24% | |||||||||
|
‡ System has been tested and operates at the specified recovery rating under standard test conditions as specified in the Performance Data Sheet. The recovery system is a percentage measure of the amount of influent water which is delivered as permeate under open permeate discharge conditions. |
||||||||||||||||
| CONDITIONS FOR SYSTEMS USE | ||||||||||||||||
| Source Water Supply Profile | Chemical Parameters | Maximum MG/L |
Application Guidelines |
|||||||||||||
| Community / Private | Chlorinated / Non-Chlorinated | Hardness (CaCo3) | <350 | This
drinking water system is for use on potable water supplies only.
CAUTION: Do not use this system where the water is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system. Source water exceeding Chemical Parameters requires pretreatment. |
||||||||||||
| System Pressure | 280-690 kPa (4--100 psig) | Iron (Fe) | <0.1 | |||||||||||||
| Temperature | 4°-38° (40°-100°) | Manganese (Mn) | <0.5 | |||||||||||||
| pH Range | 3.0-11.0 | Hydrogen Sulfide (H2S) | 0.00 | |||||||||||||
| Maximum TDS Level | 2000 mg/L | Residual Chlorine (Cl2) | <2.0 | |||||||||||||
| Turbidity | <1.0 NTU | °Silt Density Index: Value stated in units. | ||||||||||||||
| Maximum SDl ° <4.0 | ||||||||||||||||
|
Warranty:
PURA warrants all new products to be free
from defects in material and workmanship. PURA systems are warrantied
for 3 years from the date of purchase except electrical components which are
warrantied for 1 year. Filters are not warrantied due to varying water
conditions. This warranty agreement excludes all products or component parts that, in the opinion of PURA, have been subjected to negligent use, misuse, or alteration, or that have been repaired with component parts other than those manufactured or supplied by PURA. This warranty gives the buyer specific rights. These rights vary from state to state. |
||||||||||||||||
All Information Copyright © 2001 by Filter Pure Systems Inc. - All Rights Reserved
Filter Pure Systems, Inc.
5405 Boran Place
Tampa, FL 33610
Ph. 813.626.9600 * Fax. 813-626-4800
E-Mail: info@filterpure.com